Jump to the main content block

Pressure Regulating Valve HG /SV Series

 Conventional Valve

Pressure Regulating Valve HG/SV Series 

Pressure Regulating Valve Model: HG-06-3-D4-P-30/ HCG-03-3A3/ HG-03-2B2/ HG-06/ SV-06G-3A

MODEL NUMBER DESIGNATION

 

SPECIFICATION

Model Number

Rated Pressure

Rated Flow

Connecting PT.

N.W. (KG)

T.Type

G.Type

HCG-03*-*-*-30

HG-03*-*-*-30

210 kgf/cm²

50 /min

3/8”

4.1

3.5

HCG-06*-*-*-30

HG -06*-*-*-30

125 /min

3/4”

7.1

6

 

ACCESSORIES (G TYPE)

Model Number

Hex. Counter-Sink Screw

HCG-03

M10 x 80L (4pcs)

HG -03

M10 x 50L (4pcs)

HCG-06

M10 x 80L (4pcs)

HG -06

M10 x 50L (4pcs)

 

 EXPLANATION OF MODEL PERFORMANCE

Valve Name

Model No.

Model A1 Counterbalance Valve

HG - *** - A1 – 30

Model B2 Sequence & Check Valve

HG - *** - B2 – 30

Model C3 Sequence & Check Valve

HG - *** - C3 – 30

Model D4 Counterbalance Valve

HG - *** - D4 - 30

Pressure Piloted & Residual Oil Leak Back

Inner pilot / Inner Leakage

Inner Pilot / Outer Leakage

Outer Pilot / Outer Leakage

Outer Pilot / Inner Leakage

Construction & Action Drawing

Hyd. Symbol

Illustration

Apply the inner pilot pressure be over the setted spring pressure, for then, the balance piston shaft upward and open the circuiting of 1st pressure & 2nd pressure, the 2nd pressure connecting the oil tank, so that, that is a direct relief valve, but these valves be installed in the hyd. Circuiting scarcely.

 

By sequence action, there are two by pass circuiting in the hyd. Circuiting, and adopts inner pilot, for then in sequence action for circuiting. If you want the and pressure backward to the 1st pressure, you must apply the check type sequence valve.

The inner & outer piloted, but the action & principle is same as the sequence valve.

In the four models, the unloading valve is widely used, the combination output capacity for the large displacement low pressure pump & little displacement high pressure pump make the action of hydraulic cylinder fast, during hyd. Cylinder the pressure advance and high pressure pump pilot the pressure to the piston rod, the output of low pressure pump was released to the oil tank, and hyd. pump being unload.

 

 

 

 

HG-03 / SV-03

 

 

 

  

DIMENSIONS / SVC-03G / SVC-06G

 

 

Model

A

B

C

D

E

F

G

H

I

Screw

HCG-03

190

170

55.5

90

35

88

P18

P10

60

M10 x 70L

HCG-06

224

197

55.5

101

42

107

P28

P10

70

M10 x 80L

 

Model

A

B

C

D

E

F

G

H

J

K

L

N

Q

HG-03T

41

82

60

74

191

57

106

43

70

0

28

28

3/8

HG-06T

48

96

73

87

221

64.5

123.5

50.5

80.5

9

33

33

3/4

HG-10T

66

132

86

112

272

84

149

66

98

12

40

40

1 1/4

 

Model

A

B

C

D

E

F

Screw

HG-03

190

160

41

67

88

P18

M10 x 50L

HG-06

230

192

41

80

96

P28

M10 x 80L

HG-10

280

235

40

92

117

P36

M10 x 90L

Click Num: